Explosion-proof uninterruptible power source SHGVA-IBP
PURPOSE AND SCOPE OF APPLICATION
Explosion-proof uninterruptible power sources SHGVA-IBP are intended for 12V DC power supply of explosion-proof electrical equipment.
The housing of SHGVA-IBP is made from modified corrosion-resistant aluminum-silicon alloy, resistant to salt spray and other chemical substances. Antistatic polymer epoxy powder coating is used for coating. Coating color is RAL 7035.
ADVANTAGES
- The battery could be easily replaced.
- Light indication of operating mode.
- Green indicator light – input voltage in case of AC.
- Red indicator light – output voltage and control of normal state of storage battery.
- High reparability due to access to all parts.
- All parts are rigidly fixed onto internal frame.
Light fixtures with SHGVA-IBP explosion-proof uninterruptible power source may be applied for creation of auxiliary and emergency lighting systems.
Marking:
1Ex db IIC T6...T5 Gb
Ex tb IIIC T80°С...T100°С Db
Certificates and permits:
ТУ 27.20.20-035-72453807-2017
Ambient temperature, °С:
-60...+60 (for SHGVA-IBP 3.2 A*h
-60…+50 (for SHGVA-IBP 7 A*h)
Maximum voltage, V:
in: ~140-230
out: ⎓ 12
Maximum load current, A:
3 (for SHGVA-IBP 3.2 A*h)
5 (for SHGVA-IBP 7 A*h)
Rechargeable battery capacity:
3,2; 7
Electric shock hazard protection class:
I
Weight, kg:
5,9 (for SHGVA-IBP 3.2 A*h); 7,1 (for SHGVA-IBP 7 A*h)
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3,T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
Name |
Dimensions, mm |
Mass, kg |
А |
В |
С |
Е |
D |
SHGVA-IBP 3,2 |
404 |
225 |
205 |
310 |
200 |
5,9 |
SHGVA-IBP 7 |
424 |
225 |
205 |
310 |
200 |
7,1 |
WIRING DIAGRAM OF SHGVA-IBP
OPTIONS, ACCESSORIES AND VERSIONS
ORDER CREATION
Non-explosion-proof version
/PROM
External surface coating as per customer’s specification
/RAL (___)
Heating for automation
/OBOGREV
The power supplies are designed for an input voltage of 127 volts AC
/127
FORMATION OF ORDERFor order of SHGVA-IBP with input box (without light fixture):
SHGVA-IBP |
- |
Х |
- |
Х |
/ |
Х |
– ТУ 3400-005-72453807-07 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product name |
|
|
|
|
|
|
|
Rechargeable battery capacity: 3,2; 7; |
|
|
|
|
|
|
|
Number, cable gland dimension type |
|
|
|
|
|
|
|
Options, accessories and versions |
The principle of operation is as follows:
- Normal mode - there is supply voltage in the mains. In this moment the storage battery is being charged. Power supply to devices (light fixtures, etc.) connected to UPSs is performed from supply voltage through converter 220-12V. Glowing of green indicator (input voltage in case of DC mains) and red indicator (normal power level of storage battery) can be observed on SHGV-IBP.
- Emergency mode - no supply voltage in the mains. In this moment the devices (light fixtures, etc.) connected to UPSs are powered by the storage battery. Green LED is off and constant glowing of red indicator (output voltage in case of operation from the storage battery) only can be observed on SHGV-IBP.
- K1 relay control circuit is extended to terminals 1; 2, for connection of remote circuit breaker which is individual for each SHGV-IBP. When the circuit breaker is connected, notwithstanding the operation mode, the light fixture is off only after its contact is closed. By default, there is a jumper between terminals 1; 2.
- The UPS automatically switches to storage battery powered mode in case of loss of supply voltage.
- The UPS automatically switches to mains-fed operation mode in case of restoration of supply voltage.
SGJ01-1240S/IBP, SGJ01-2480S/IBP, SGJ01-3720S/IBP
SGJ01-4960S/IBP, SGJ01-6200S/IBP, SGJ01-7440S/IBP
SGU01-1240S/IBP, SGU01-2480S/IBP, SGU01-3720S/IBP
SGU01-4960S/IBP, SGU01-7440S/IBP
SGM02-1860S/20-220AC/IBP, SGM02-1860S/90-220AC/IBP
SGU02-7440S.../IBP
Name |
Overall dimensions, mm |
Mass, kg |
A |
B |
C |
D |
E |
SGJ01-1240S/IBP |
400 |
225 |
330 |
200 |
310 |
11,5 |
SGJ01-2480S/IBP |
SGJ01-3720S/IBP |
SGJ01-4960S/IBP |
500 |
235 |
380 |
200 |
310 |
15 |
SGJ01-6200S/IBP |
SGJ01-7440S/IBP |
SGU01-1240S/IBP |
425 |
225 |
200 |
200 |
310 |
13 |
SGU01-2480S/IBP |
SGU01-3720S/IBP |
SGU01-4960S/IBP |
525 |
275 |
205 |
200 |
310 |
17,5 |
SGU01-7440S/IBP |
SGM02-1860S/20-220AC/IBP |
440 |
225 |
200 |
200 |
310 |
10,5 |
SGM02-1860S/90-220AC/IBP |
SGU02-7440S/IBP |
325 |
400 |
185 |
200 |
310 |
16,5 |
* Chracteristics of storage batteries for other series of Goreltex light fixtures are provided by request.
Table of matching
Picture |
Name |
Storage battery capacity, А*h |
Approximate operating time in emergency mode, hours |
|
SGJ01-1240S/IBP |
3,2 |
3 |
SGJ01-2480S/IBP |
3,2 |
1,5 |
SGJ01-3720S/IBP |
3,2 |
1 |
SGJ01-4960S/IBP |
7 |
1,8 |
SGJ01-6200S/IBP |
7 |
1,4 |
SGJ01-7440S/IBP |
7 |
1,2 |
|
SGM02-1860S/20-220AC/IBP |
3,2 |
2,5 |
SGM02-1860S/90-220AC/IBP |
3,2 |
2,5 |
|
SGU01-1240S/IBP |
3,2 |
3 |
SGU01-2480S/IBP |
3,2 |
1,5 |
SGU01-3720S/IBP |
3,2 |
1 |
SGU01-4960S/IBP |
7 |
1,8 |
SGU01-7440S/IBP |
7 |
1,2 |
|
SGU02-7440S.../IBP |
7 |
1,8 |
GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST 30852.1-2002 (IEC 60079-1:1998), GOST IEC 61241-1-1-2011, Ch. 7.3 PUE, Ch. 7.4 PUE, RD 5.2-093-2004, TR CU 012/2012