• Distribution and terminal boxes Distribution and terminal boxes
  • Control and automation cabinets Control and automation cabinets
  • Lighting equipment Lighting equipment
  • Control and indication posts Control and indication posts
  • Light, sound and signaling devices Light, sound and signaling devices
  • Electric heating and fans Electric heating and fans
  • Video Surveillance Video Surveillance
  • IT equipment IT equipment
  • Spark protection barriers and safety relays Spark protection barriers and safety relays
  • Cable entries, pipe wiring Cable entries, pipe wiring
  • Connectors, plugs, extension cords Connectors, plugs, extension cords
  • Switches, switches, sensors Switches, switches, sensors
  • Control and measuring devices Control and measuring devices
  • Cable/pipe penetrations Cable/pipe penetrations
  • Electrical components and materials Electrical components and materials
White WaveDesign logo

Explosion-proof bimetallic thermostats DVG-TERMOSTAT1

Product Description

Bimetallic thermostats DVG-TERMOSTAT1 are designed to collect information and control the external temperature of heating systems, and regulate the internal temperature of heated instrument cabinets at explosive facilities.

Strengths

  • Suitable for controlling both heating and cooling systems;
  • Possibility of manufacturing based on housings of other sizes;
  • Controls loads up to 10A directly;
  • Switching on higher values ​​or 3-phase circuits is accomplished through a contactor;
  • Possibility of installing up to 3 cable entries.

Customers who bought this item also ordered

Compliance

TR CU 012/2011
TR CU 004/2011
GOST Р МЭК 60079-0-2011
GOST 14254-96 (IEC 529-89)
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.8-2002 (IEC 60079-0:1998)
GOST IEC 61241-1-1-2011
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST Р МЭК 60079-31-2010
GOST 30852.10-2002 (IEC 60079-11:1999)

Certificates

Maritime Register upon request (contact the manager for the cost and timeframe for obtaining the STO)

Markings

Explosion protection marking
1Ex db IIC T6...T5 Gb
1Ex ia IIC T6...T5 Gb
0Ex ia IIC T6…T5 Ga X
Ex tb IIIC T85°С...T100°С Db
Ex ia IIIC T85°C...T100°C Da
Marking of mining equipment
RN1/RN2
Degree of protection
IP66 / IP67
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres, volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous due to gas (methane) and coal dust;
Non-explosive zone of above-ground buildings and open areas

Technical data

Ambient temperature, °C
-60...+85 (T5/T100°C)
-60...+60 (T6/T85°C)
Electrical specifications
Un= ~380 V, In=4 A, f=50 Hz
Un= ~220 V, In=10 A, f 50 Hz
Un= 30 V, Iн=10 A
Grounding
2 ground clamps (internal and external) made of stainless steel
Fastening the lid
Threaded connection
Покрытие
Polymer-epoxy paint with antistatic properties, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Material
Aluminum alloy with alloying modifiers
Housing fastening
2 external mounting points
Class of protection against electric shock
I
Weight, kg
1,5
Climatic performance
UHL1 (as required by UHL2, UHL3, UHL4, UHL5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, OM1, OM2, OM3, OM4, B2.1, B5)

Design parameters

Explosion-proof junction boxes for energy distribution and data collection DVG-TERMOSTAT1 (S-TERMOSTAT)

Response graph using the example of DVG-TERMOSTAT1-(21/17)0

Response graph using the example of DVG-TERMOSTAT1-(21/17)0

Thermostat type Contact type Response ranges
DVG-THERMOSTAT1-(60/78)1 1NZ 60-68°C...72-78°C
DVG-THERMOSTAT1-(0/18)1 1NZ 0-8°C...12-18°C
DVG-THERMOSTAT1-(-5/13)1 1NZ -5-3°C...7-13°C
DVG-THERMOSTAT1-(21/17)0 1NO 21-29°C...11-17°C
DVG-THERMOSTAT1-(2/-2)0 1NO 2-8°C...-10- -2°C
DVG-THERMOSTAT1-(66/62)0 1NO 66-74°C...56-62°C

Options

Options, accessories and versions
Marking
Degree of protection against external influences IP67
/IP67
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Marine performance
/SEA
Non-explosion-proof design
/PROM
River execution
/RIVER
Mine normal execution
/RN
Mounting bracket
/BRACKET
Stainless steel lid chain
/CHAIN

3D models

Additional Information

Leave a request

Quantity
Additional description
0 / 300

Drag files here

CAD "GorelTekh", questionnaires, necessary documents

Remaining: 20.00 MB
or
More about mnemonics
1X ( 2X ) - 3X / 4X – TU 27.12.31-037-72453807-2017
1X - Thermostat type
2X - Number and cross-section of terminals
3X - Number of cable entries (max. 3 pcs) and side of location
4X - Options, accessories and versions

Example: DVG-TERMOSTAT1-(2/-2)0 (4RN2) - KNV2N(A) -TU 27.12.31-037-72453807-2017

where DVG-THERMOSTAT1-(2/-2)0 - thermostat type,
4RN2 - number of terminals and their cross-section,
KNV2N(A) - quantity, type and side of cable entry location.