Explosion-proof portable light fixtures SGR01 consist of aluminum enclosure with built-in socket and fire- and impact-resistant globe which is mounted to the body by means of thread. Light fixtures have eye bolt or a hook for suspension.
Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), areas with presence of combustible dust, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.
SGR01 | - | Х | Х | - | Х | / | Х | /KXХ /X | – TU 27.40.39-028-72453807-2017 | |
Type of device | ||||||||||
Lamp power | ||||||||||
Lamp type: incandescent lamp - INC; Compact fluorescent with spiral tube - ELS; LED lamp - S; LED matrix - S |
||||||||||
Supply voltage, V: 12AC, 12DC; | ||||||||||
Number of light fixtures: 1; 2; 3 | ||||||||||
Options, accessories, versions, where: /KXX - cable dyne in meters (required) /X - other options, accessories and versions |
EXAMPLE OF ORDER:SGR01-2480S-12DC/1/К40/KRYUK-TU 27.40.39-028-72453807-2017
SHGVA-BP-SGR01 | - | Х | - | Х | - | Х | / | Х | – TU 27.12.31-048-72453807-2017 |
Type of device | |||||||||
Number of sockets: 1; 2; 3 | |||||||||
Supply voltage, V: 12AC; 12DC; | |||||||||
Dimension type of cable gland | |||||||||
Options, accessories and versions |
EXAMPLE OF ORDER: SHGVA-BP-SGR01-3-12DC-KOV1N-TU 3400-006-72453807-07
EXAMPLE OF ORDER: SHGVA-BP-SGR01-1-12DC-KOV1N-TU 27.12.31-048-72453807-2017
Supply voltage 12 V | Cable length, m | ||||||||||||
5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | ||
Light source power, W: | 10 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,5 | 1,5 | 1,5 | 1,5 | 2,5, | 2,5 |
20 | 1,0 | 1,0 | 1,0 | 1,5 | 1,5 | 2,5 | 2,5 | 2,5 | 4,0 | 4,0 | 4,0 | 4,0 | |
40 | 1,0 | 1,5 | 2,5 | 2,5 | 4,0 | 4,0 | 6,0 | 6,0 | 6,0 | 6,0 | |||
60 | 1,0 | 2,5 | 4,0 | 4,0 | 6,0 | 6,0 | |||||||
100 | 1,5 | 4,0 | 6,0 | 6,0 | |||||||||
150 | 2,5 | 6,0 | |||||||||||
200 | 4,0 | 6,0 |
Supply voltage 24 V | Cable length, m |
||||||||||||
5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | ||
Light source power, W: |
10 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 |
20 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | |
40 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,0 | 1,5 | 1,5 | 1,5 | 1,5 | 2,5 | 2,5 | |
60 | 1,0 | 1,0 | 1,0 | 1,0 | 1,5 | 1,5 | 2,5 | 2,5 | 2,5 | 2,5 | 2,5 | 4,0 | |
100 | 1,0 | 1,0 | 1,5 | 1,5 | 2,5 | 2,5 | 4,0 | 4,0 | 4,0 | 4,0 | 6,0 | 6,0 | |
150 | 1,0 | 1,5 | 2,5 | 2,5 | 4,0 | 4,0 | 4,0 | 6,0 | 6,0 | 6,0 | |||
200 | 1,0 | 1,5 | 2,5 | 4,0 | 4,0 | 6,0 | 6,0 |
Type of cable | Cable outer diameter | Cable gland type |
KG 3х1,0 | 9,1 | KNV1 |
KG 3х1,5 | 10,1 | KNV1 |
KG 3х2,5 | 12 | KNV2 |
KG 3х4 | 14,5 | KNV2 |
KG 3х6 | 16,6 | KNV2 |