Explosion-proof rectangular LED display PGS-IT35
Product Description
The explosion-proof PGS-IT35 LED information light boards can be used as warning signs, issuing visual alerts in hazardous areas to guide human behavior both during normal operation and in emergency situations. They can also be integrated into fire alarm and automatic fire suppression systems.
Strengths
- Certified equipment ensuring safety and uninterrupted operation.
- The aluminum alloy housing with alloying modifiers combines exceptional mechanical strength and corrosion resistance. The window is made of impact-resistant tempered glass.
- The compact size of the housing allows the alarm to be installed in a limited space.
- Operation in emergency mode from a battery is possible.
- Many options of inscriptions upon customer request.
- Wide range of power supply voltage: 12DC, 24DC, 48DC 12AC, 220DC, 24AC, 127AC, 220AC.
- Protection against mechanical damage IK10 and a high degree of protection against moisture and dust IP66/IP67/IP69.
Customers who bought this item also ordered
Compliance
CONFORMITY WITH STANDARDS GOST 12.2.007.0-75
SSBT
GOST 31610.0-2014 (IEC 60079-0:2011)
GOST IEC 60079-1-2013
GOST IEC 60079-31-2013
GOST 22782.3-77
GOST IEC 60079-14-2013
GOST 14254-2015
GOST 24754-2013
GOST 30852.20-2002
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
TR CU 012/2011
TR CU 004/2011
EAEU TR 043/2017
GOST 30546.1-98
GOST 30546.2-98
GOST 30546.3-98
IECEx CCVE 19.0005X
IEC 60079-0: 2011
IEC 60079-1:2014-06
IEC 60079-31: 2013
EN 60079-0:2012/A11:2013
IN 60079-1: 2014
EN IEC 60079-7:2015/A1:2018
EN 60079-18:2015/A1:2017
IN 60079-31: 2014
Certificates
TU 3400-006-72453807-07
TU 27.90.20-038-72453807-2017
Markings
Explosion protection marking
1Ex db IIC T6 Gb X
Ex tb IIIC T80°C Db XMarking of mining equipment
RN1/RN2
Degree of protection
IP66 / IP67
IK10
IK10
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust environments containing volatile particles of non-conductive and conductive dust;
Underground workings that are not hazardous due to gas (methane) and coal dust
Category III for dust, explosive dust environments containing volatile particles of non-conductive and conductive dust;
Underground workings that are not hazardous due to gas (methane) and coal dust
Technical data
Ambient temperature, °C
-60 ... + 60
Rated voltage, V
~220; ~127 ; ⎓12; ⎓24; ⎓48; ⎓220;
Current consumption, A
0,28 (for ⎓12 V); 0,02 (for ⎓220 V); 1,8 (for ⎓12 V with /UPS option)
0,14 (for ⎓24 V); 0,11 (for ⎓48 V); 0,9 (for ⎓24 V with /UPS option)
0,05 (for ~220 V); 0,57 (for ~127 V); 0,33 (for ~220 V with /UPS option)
0,14 (for ⎓24 V); 0,11 (for ⎓48 V); 0,9 (for ⎓24 V with /UPS option)
0,05 (for ~220 V); 0,57 (for ~127 V); 0,33 (for ~220 V with /UPS option)
Power, W
8 (for ~220 V), 7 (for ⎓12 V)
Connection holes
4 x M25x1,5 (3 x M25x1,5 for battery version)
Покрытие
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Housing material
Aluminum alloy with alloying modifiers. Window - impact-resistant glass.
Housing fastening
4 external mounting points
Power factor (cos φ)
0,75
Brightness (green backlight)
Not less than 1200 cd/m2.
Class of protection against electric shock
I
Weight, kg
9,8
Climatic performance
UHL1 (as required by UHL2, UHL3, UHL4, UHL5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, OM1, OM2, OM3, OM4, B2.1, B5)
Design parameters

Light board PGS-IT35 with UPS option

Lighted board PGS-IT35 with a canopy option

Options
Additional Information
Typical inscriptions used in illuminated boards *
| Red letters, black background | White letters, red background | White letters (symbols), green background |
| FIRE DO NOT ENTER GAS GAS GO AWAY! DO NOT ENTER AEROSOL AEROSOL GO AWAY! DO NOT ENTER POWDER POWDER GO AWAY! FOAM GO AWAY! DO NOT ENTER FOAM BEWARE OF THE ELECTRIC TRAIN! |
FIRE DO NOT ENTER GAS GAS GO AWAY! DO NOT ENTER AEROSOL AEROSOL GO AWAY! DO NOT ENTER POWDER POWDER GO AWAY! FOAM GO AWAY! DO NOT ENTER FOAM BEWARE OF THE ELECTRIC TRAIN! |
AUTOMATION IS DISABLED EMERGENCY EXIT OUTPUT EXIT EXIT TO THE LEFT EXIT TO THE RIGHT Symbolic designation of input and output |
* We will produce any inscription or pictogram, standard or custom.
Leave a request
Quantity
Additional description
0 / 300
Drag files here
CAD "GorelTekh", questionnaires, necessary documents
or
PGS-IT35 - 1X / 2X / 3Х / 4Х - 5Х / 6Х – TU 27.90.20-038-72453807-2017
1X - Supply voltage: ⎓12 V - 12 DC; ⎓24 V - 24DC; ⎓48 V - 48DC; ⎓220-230V - 220DC; ~127 V - 127AC; ~220 V - 220AC
2X - Inscription (or pictogram code according to GOST 12.4.026-2015)
3X - Inscription color: White - Б; Red - К; Yellow - Ж; Green - З; Blue - С; Black - Ч
4X - Background color: White - B; Red - K; Yellow - Y; Green - Z; Blue - S; Black - B
5X - Number and size of cable entries
6X - Options, accessories and versions
Example: ПГС-ИТ35-220AC/ВЫХОД/Б/З-1КНВ1MНК/КОЗЫРЁК-ТУ 27.90.20-038-72453807-2017
EAEU RU C-RU.AA87.B.01557/25
IECEx CCVE 19.0005X
EESF 19 ATEX 035X
EAEU N RU D-RU.PA11.V.91695/25
ROSS RU C-RU.MY62.V.00095/23
EAEU RU C-RU.PB74.V.00150/20
RU.OC VSST 0181-12-2023
OGN4.RU.1104.B03579
GOST R ISO 9001-2015 (ISO 9001:2015)