• Distribution and terminal boxes Distribution and terminal boxes
  • Control and automation cabinets Control and automation cabinets
  • Lighting equipment Lighting equipment
  • Control and indication posts Control and indication posts
  • Light, sound and signaling devices Light, sound and signaling devices
  • Electric heating and fans Electric heating and fans
  • Video Surveillance Video Surveillance
  • IT equipment IT equipment
  • Spark protection barriers and safety relays Spark protection barriers and safety relays
  • Cable entries, pipe wiring Cable entries, pipe wiring
  • Connectors, plugs, extension cords Connectors, plugs, extension cords
  • Switches, switches, sensors Switches, switches, sensors
  • Control and measuring devices Control and measuring devices
  • Cable/pipe penetrations Cable/pipe penetrations
  • Electrical components and materials Electrical components and materials
White WaveDesign logo

Explosion-proof control and indication posts PKIE-P according to the customer's design made of reinforced polyamide

Product Description

The PKIE-P series explosion-proof control and indicator stations with Ex e protection rating are made of impact-resistant, fiberglass-reinforced polyamide with antistatic modifiers and are designed to control various equipment in hazardous areas. Suitable for use in underground mines and workings.
The PKIE-N series control and indicator stations have received a SIL 2 functional safety certificate. This certification confirms that the equipment operates reliably during operation, ensures functional safety, and can be used in emergency shutdown systems (ESPS). When ordering the equipment, please specify the "/SIL2" option and indicate its intended purpose in the comments: emergency stop, emergency start, or a combination of both. Whether the "/SIL2" option is applicable depends on the control station configuration.

Strengths

  • Certified equipment ensuring safety and uninterrupted operation.
  • The body is made of impact-resistant, fiberglass-reinforced polyamide with antistatic modifiers, resistant to working environments.
  • A flexible modular system of posts is achieved by using various housing sizes and a variety of control and indication modules.
  • There is a wide selection of control, indication, monitoring and notification elements of standard design, as well as non-standard designs, manufactured according to customer requirements.
  • Bright colours for the visual part of the control and indicator elements – buttons, lamps, etc.
  • Protection against mechanical damage IK08 and a high degree of protection against moisture and dust IP66/IP69.

Customers who bought this item also ordered

Compliance

GOST 12.2.007.0-75
GOST 31610.0-2014
GOST IEC 60079-1-2013
GOST Р МЭК 60079-7-2012
GOST 31610.11-2014 (IEC 60079-11:2011)
GOST Р МЭК 60079-18-2012
GOST IEC 60079-31-2013
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST 30852.8-2002 (IEC 60079-0:1998)
GOST 30852.10-2002 (IEC 60079-11:1999)
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 30852.20-2002
TR CU 012/2011
TR CU 004/2011
GOST 14254-2015

Certificates

Markings

Explosion protection marking
 1Ex eb IIC T6...T5 Gb
 1Ex db eb IIC T6...T5 Gb
 1Ex eb mb IIC T6...T5 Gb
 1Ex db eb mb IIC T6...T5 Gb
 1Ex ia IIC T6...T5 Gb
 0Ex ia IIC T6...T5 Ga X
 0Ex ia IIC T6...T5 Ga
 1Ex db eb ib IIC T6...T5 Gb
 1Ex db eb ia IIC T6...T5 Gb
 1Ex eb ib mb IIC T6...T5 Gb
 1Ex db eb ia IIC T6...T5 Gb
 1Ex eb ia mb IIC T6...T5 Gb
 1Ex db eb ia mb IIC T6...T5 Gb
 Ex ia IIIC T85°C...T100°C Da
 Ex tb IIIC T85°C...T100°C Db
 Ex ia tb IIIC T85°C...T100°C Db
 Ex ib tb IIIC T85°C...T100°C Db
Marking of mining equipment
 PO Ex ia I Ma
 RP Ex db eb I Mс
 RP Ex db eb ib I Mc
 RP Ex db eb ia I Mc
 RP Ex eb mb I Mc
 RP Ex db eb mb I Mс
 RP Ex eb I Mc
RN1/RN2
Degree of protection
IP66K
IK08
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 0, 1, 2;
Category III for dust, explosive dust environments containing volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous due to gas (methane) and coal dust;
Non-hazardous area

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+60 (for normal mine and general industrial designs)
Maximum voltage, V
~690 / ⎓250
Maximum current, A
290
Placement of cable entries
According to customer specifications. These types of posts do not use cable entries with tapered threads.
Housing material
Impact-resistant, glass fiber-reinforced polyamide with antistatic modifiers
Climatic performance
UHL1 (as required by UHL2, UHL3, UHL4, UHL5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, OM1, OM2, OM3, OM4, B2.1, B5)

Design parameters

Overall and connection dimensions of PKIE-P100809, PKIE-P141210, PKIE-P161609

PKIE-P100809, PKIE-P141210, PKIE-P161609

Overall and connection dimensions of PKIE-P170809, PKIE-P211311, PKIE-P221512, PKIE-P221515, PKIE-P261812, PKIE-P302113, PKIE-P332212, PKIE-P332215, PKIE-P362216, PKIE-P363616, PKIE-P423019

PKIE-P170809, PKIE-P211311, PKIE-P221512, PKIE-P221515, PKIE-P261812, PKIE-P302113, PKIE-P332212,
PKIE-P332215, PKIE-P362216, PKIE-P363616, PKIE-P423019

Overall and connection dimensions of PKIE-P723616, PKIE-P723622, PKIE-P723624

PKIE-P723616, PKIE-P723622, PKIE-P723624

Dimensions of PKIE-P post housings made of reinforced polyamide
Standard size
housing
Maximum amount
control and indicator elements
on the case cover*
A B C D d E I Body weight, kg
PKIE-P100809 1 105 85 96 73 6 70 - 0,6
PKIE-P170809 2 175 85 95 73 4,8 138 - 0,6
PKIE-P141210 3 148,5 129,5 109 118 8 105,5 - 1,2
PKIE-P161609 4 160 160 92,5 148 8 19 - 1,8
PKIE-P211311 To be specified when ordering 210 129,5 106,5 116 7 166 - 1,5
PKIE-P221512 6 224,5 149,5 121 135 6,6 182 - 1,7
PKIE-P221515 6 224,5 149,5 151 135 6,6 182 -  1,8
PKIE-P261812 9 259,5 180 121 163,5 6,6 217 -  2,0
PKIE-P302111** 10 299 209 107 195 6,6 254 - 2,4
PKIE-P302113 10 299 209 134 195 6,6 254 - 2,9
PKIE-P332212** 16 329,5 224 123 210 6,6 286 -  3,0
PKIE-P332215 16 329,5 224 153 210 6,6 285 -  3,1
PKIE-P362216 18 360 220 160,5 203 8,8 300 -  4,5
PKIE-P363616 27 360 360 161,5 342 8,8 297 - 6,0
PKIE-P423019 25 420 300 187,5 287,5 8,8 362 - 6,5
PKIE-P723616 To be specified when ordering 720 360 162 335 8,8 311 347 12,5
PKIE-P723622 To be specified when ordering 720 360 221 331 8,8 311 347  13,5
PKIE-P723624 To be specified when ordering 720 360 243 332 8,8 311 347 13,5

*The number of installed elements depends on their dimensions and contact group sizes. The exact number of elements and housing size for a specific solution are specified when placing an order. Modular explosion-proof control panels can be manufactured according to the customer's specifications.
**Please check availability and lead times for these sizes with the manager.

Options

Options, accessories and versions
Marking
Functional safety equipment component
/SIL2
Ventilation device for moisture removal
/VKU
Drainage ventilation devices
/DKUE
Lid lock
/LOCK
Marine performance
/SEA
A plate with the customer's inscription
/INSCRIPTION "_"
Fire alarm light (the product consists of only lamps and one button for testing the lamps)
/OP
Fixing the lid on hinges
/LOOP
Mounting plate
/PLANK
Bolt with seal
/SEAL
Component of block-modular polyurethane foam
/PPU
Non-explosion-proof design
/PROM
Internal plate for strengthening the fastening of cable entries and continuity of the earth circuit
/OCOR
Mounting plate with holes
/RAIL
River execution
/RIVER
Mine normal execution
/RN
Tropical version with insect protection
/TERMITES
Remote start device for manual starting of fire extinguishing system
/UDP

3D models

STP models
zip
Download

Additional Information

Leave a request

Quantity
Additional description
0 / 300

Drag files here

CAD "GorelTekh", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact the sales department Download the questionnaire Configure in CAD
More about mnemonics
PKIE-P 1Х - 2Х 3Х ... 2Х 3Х - 4Х 5Х ( 6Х ) - 4Х 5Х ( 6Х ) / 7Х – TU 27.12.31-037-72453807-2017
1X - Case size
2X - Number of controls and indicators
3X - Type of controls and indicators
4X - Number of cable entries
5X - Cable entry type
6X - Input location side Sides of the location of cable entries
7X - Options, accessories and versions

If the "enclosure size" is not specified, a case will be selected that is optimally suited to the layout of the specified set of components. The number of components is specified when installing multiple identical units.

Example: ПКИЕ-П161609-2КГЕ01К20-КГЕ07К20-2КНЕП01(В)-ТУ 27.12.31-037-72453807-2017
- Case size: PKIE-P161609
- Two "2" push buttons without locking, black, contacts 2NO: 2KGE01K20
- Mushroom button with locking, unlocking by rotation, 2NO contacts: KGE07K20
- Two "2"s cable entries, size "KNEP01", location side "(B)": 2KNEP01(V)
- TU 27.12.31-037-72453807-2017