• Distribution and terminal boxes Distribution and terminal boxes
  • Control and automation cabinets Control and automation cabinets
  • Lighting equipment Lighting equipment
  • Control and indication posts Control and indication posts
  • Light, sound and signaling devices Light, sound and signaling devices
  • Electric heating and fans Electric heating and fans
  • Video Surveillance Video Surveillance
  • IT equipment IT equipment
  • Spark protection barriers and safety relays Spark protection barriers and safety relays
  • Cable entries, pipe wiring Cable entries, pipe wiring
  • Connectors, plugs, extension cords Connectors, plugs, extension cords
  • Switches, switches, sensors Switches, switches, sensors
  • Control and measuring devices Control and measuring devices
  • Cable/pipe penetrations Cable/pipe penetrations
  • Electrical components and materials Electrical components and materials
White WaveDesign logo

Explosion-proof room heaters GTG-RADIATOR

Product Description

GTG-RADIATOR heaters are designed to heat and maintain a positive (set) temperature in process rooms, automation cabinets, and units with control and measuring equipment and other equipment that require a positive temperature for normal operation.

Plate heaters provide uniform heating of enclosed spaces. They are explosion-proof and reliable, eliminating direct contact between the heating elements and the installed equipment. A flat, explosion-proof silicone heating element is mounted on an aluminum plate within a protective perforated metal casing. More efficient heating is ensured by installing an additional, specially insulated layer where the plate attaches to the casing.

The GTG-RADIATOR heating element is a vibration-resistant, corrosion-resistant silicone plate. Thanks to its flat design, the heater does not accumulate dust.

Scope of application: hazardous areas of premises and outdoor installations, and mines that are not hazardous due to gas or dust, according to explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) and areas hazardous due to ignition of combustible dust, according to GOST IEC 61241-3-2011, hazardous production facilities of I, II, III, IV hazard classes, supervised by Rostekhnadzor of the Russian Federation and national technical supervision agencies of the CU and CIS countries.

Strengths

  • Safe design: the casing prevents direct contact between the heating element and the equipment. Dust-proof: the flat heating element design prevents dust accumulation. Corrosion resistance: the silicone heating element is corrosion-resistant. Vibration resistance: reliable operation under vibration and mechanical stress. Versatility: suitable for indoor and outdoor installations in hazard classes I-IV.

Customers who bought this item also ordered

Compliance

GOST 31610.0-2014 (IEC 6079-0:2011)
TR CU 012/2011
TR CU 004/2011
TR CU 020/2011
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
GOST Р МЭК 60079-7-2012
GOST IEC 60079-31-2013
GOST IEC 60079-30-1-2011
GOST IEC 60079-1-2013
GOST 24754-2013
GOST 30852.20-2002

Certificates

Maritime Register upon request (contact the manager for the cost and timeframe for obtaining the STO)
TU 28.21.13-041-72453807-2017

Markings

Explosion protection marking
1Ex e IIC T6....T3 Gb X
Ex tb IIIC T85°C...T200°C Db X
Marking of mining equipment
RN1/RN2
Degree of protection
IP66K
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust environments containing volatile particles, non-conductive and conductive dust;
Non-explosive zone of above-ground buildings and open areas

Technical data

Ambient temperature, °C
-60 ... + 60
Maximum supply voltage, V
~230 (50/60 Hz)
Power, W
600, 1200
Threads on connecting holes
RC 1/2" conical pipe
Electric circuit
Direct connection to terminals L, N, PE with a cross-section of 4 mm2
Working position in space
any
Class of protection against electric shock
I
Weight, kg
10
Climatic performance
UHL1 (as required by UHL2, UHL3, UHL4, UHL5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, OM1, OM2, OM3, OM4, B2.1, B5)

Design parameters

GTG-RADIATOR-600

Explosion-proof protected plate heaters GTG-RADIATOR-600

GTG-RADIATOR-1200

Explosion-proof protected plate heaters GTG-RADIATOR-1200

Options

Options, accessories and versions
Marking
Limited case temperature
/100
Marine performance
/SEA
A plate with the customer's inscription
/INSCRIPTION "_"
Non-explosion-proof design
/PROM
Mine normal execution
/RN

3D models

Revit models
zip
Download

Additional Information

Leave a request

Quantity
Additional description
0 / 300

Drag files here

CAD "GorelTekh", questionnaires, necessary documents

Remaining: 20.00 MB
or
More about mnemonics
GTG-RADIATOR - 1X - 2X / 3X – TU 28.21.13-041-72453807-2017
1X - Power, W: 600; 1200
2X - Cable entry size
3X - Options, accessories and versions

Example: ГТГ-РАДИАТОР-1200-1КНВ1MНК-ТУ 28.21.13-041-72453807-2017