Explosion-proof magnetic reed switch DVG-MV2 (PS-HERCON)

+
+
x
<
>
Explosion-proof magnetic reed switch DVG-MV2 (PS-HERCON)PURPOSE AND SCOPE OF APPLICATION

Explosion-proof magnetic reed switches DVG-MV2 are intended for closing/opening electrical circuits when a magnet is at a specified distance. The sensors are manufactured in the enclosure with type of protection "flameproof enclosure" or in intrinsically safe version and they can be applied as a control device as part of the blocking system intended for creation of local and distributed emergency shutdown systems and signalization. Explosion-proof magnetic reed switches DVG-MV2 operate faultlessly even in the harshest conditions, in places with severe pollution, high level of humidity and chemically aggressive atmospheres. The switches are resistant to high switching frequencies. Sensors are actuated contactless by a constant magnet.

Scope of application - hazardous indoor and outdoor areas in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), chapters 7.3, 7.4 of Electrical Installation Code (PUE), other regulatory documents which regulate application of electrical equipment in hazardous and non-hazardous areas at dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ Р МЭК 60079-0-2011, ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ Р МЭК 60079-31-2010, ГОСТ 30852.1-2002 (МЭК 60079-1:1998), ГОСТ 30852.10-2002 (МЭК 60079-11:1999), ГОСТ IEC 61241-1-1-2011, ГОСТ 24754-2013, ТР ТС 012/2011, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ТР ТС 004/2011, ГОСТ 30852.20-2002
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex db IIC T6...T5 Gb
0Ex ia IIC T6...T5 Ga
Ex tb IIIC T85°С...T100°С Db
Mining equipment marking:
PB Ex db I Mb
РН1/РН2
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+60 (Т6/Т85°С)
-60...+85 (Т5/Т100°С)
-60...+85 (for РН1/РН2, explosion-proof and general industrial versions)
Maximum voltage, V:
Umax=200 V
Imax=1A
Maximum current, A:
Ui=30B
Ii=1A
Material:
Nickel-plated brass resistant to hydrogen sulfide and hydrochloric
acid vapors and to salt spray
Electric shock hazard protection class:
I
Mass, kg:
0,5
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Cable (length xx)
/K xx
Ingress protection degree IP68
/IP68
Non-explosion-proof version
/PROM
+
OVERALL AND MOUNTING DIMENSIONS

Взрывозащищенные магнитные датчики ДВГ-МВ2

Device name
DVG-MV2-16-200 DVG-MV2-16-60 DVG-MV2-25-200 DVG-MV2-25-60
Electrical characteristics Contact Type Toggle Toggle Toggle Toggle
Max. current, A 1 0,25 1 0,25
Max. voltage, V 200 60 200 60
Max. load power 30 W active /
1,5 VA inductive
4 Вт 30 W active / 
1,5 ВА inductive
4 W
Diameter of a magnet in a set 16 16 25 25
Distance, C Actuation, mm 1 9 12 21
Release, mm 4 11 20 24
Coaxiality tolerance D, mm 2 4 7 7
Dimension A, mm 145* 133* 145* 133*
Dimension B, mm 32 20 32 20
*Dimensions for cable glands for armored cable. Dimensions for other types of thread shall be specified when making an order.
+
FORMATION OF MARKING
DVG-MV2  -  Х  -  Х  -  Х   Х  – TU 3400-005-72453807-07










                  Device name
                  Magnet diameter
                  Maximum voltage, V
                  Dimension type of cable gland
                  Options, accessories and versions

Example: DVG-MV2-16-200-KNV1N-TU 3400-005-72453807-07

+