Explosion-proof microwave motion sensors series DVG-SHAG (EMHA-WAKEUP)

+
x
<
>
Explosion-proof microwave motion sensors series DVG-SHAG (EMHA-WAKEUP)PURPOSE AND SCOPE OF APPLICATION

Explosion-proof motion sensors DVG-SHAG are intended for automatic load switching on and off in a given time interval if moving objects including mechanical objects appear in a sensor‘s detecting area and depending on illumination level. Explosion-proof motion sensors DVG-SHAG operate in single-phase electric power systems of 230 VAC and 50/60 Hz frequency. Explosion-proof motion sensors DVG-SHAG operate on a principle of radio location with super high frequency waves 5,8 GHz, receiving echo reflected from the objects.

Scope of application - hazardous indoor and outdoor areas in accordance with explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) and areas hazardous with combustible dust ignition as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard classes under supervision of Rostekhnadzor and national supervisory bodies of the CU and the CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ 14254-96 (МЭК 529-89), ГОСТ Р МЭК 60079-0-2011, ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.1-2002 (МЭК 60079-1:1998), ГОСТ IEC 61241-1-1-2011, Гл. 7.3 ПУЭ, ГОСТ 24754-2013, Гл. 7.4 ПУЭ, РД 5.2-093-2004, ТР ТС 012/2011, ГОСТ 12.2.007.0-75. ССБТ, РД 5.2-093-2004, ГОСТ Р МЭК 60079-31-2010
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex db IIC T6...T5 Gb
Ex tb IIIC T85°С...T100°С Db
Mining equipment marking:
РН1/РН2
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+40 (Т6/Т85°С)
-60...+60 (Т5/Т100°С)
-60...+60 (РН1/РН2 and general industrial design)
Supply voltage, V:
~220-240 (50/60 Hz)
Consumed power, W:
0,9
Rated load, W:
1200 (for incandescent and halogen lamps)
300 (for LED and fluorescent lamps)
Transmit power, mW:
< 10 (one hundredth of transmit power of a cell phone)
Thread on connecting holes:
Coating:
Antistatic polymer-epoxy coating, frictionally intrinsically safe, resistant to operating environment and ionizing radiation. Color RAL 7035
Enclosure material:
Modified corrosion-resistant aluminum-silicon alloy, resistant to salt spray and other chemical substances including hydrogen sulfide and hydrochloric acid vapors, frictionally intrinsically safe.Window - impact-resistant heat-resistant borosilicate glass.
Actuation speed, s:
0,6 - 1,5
Illumination level, lux:
3 - 2000 (regulated)
Turn-off delay, sec:
10 - 720 (regulated)
Actuation range, m:
1 - 4 (regulated)
High-frequency system, GHz:
5,8
Installation height, m:
1,5 - 3,6
Mass, kg:
4
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
External surface coating as per customer’s specification
/RAL (___)
Anti-condensation coating
/AP
Nameplates with light-reflective coating
/SVP
Fastening bracket
/SKOBA
+
OVERALL AND MOUNTING DIMENSIONS

Взрывозащищенные микроволновые датчики движения серии ДВГ-ШАГ

+
FORMATION OF MARKING
DVG-SHAG Х   Х  – TU 3400-005-72453807-07






          Product name
          Quantity and dimension types of cable glands
          Options, accessories and versions

Example: DVG-SHAG-KNV2N/AP-TU 3400-005-72453807-07.

+
WIRING DIAGRAM
Схема подключения

SETTING

Regulator of illumination level allows to set illumination level, at which motion sensor closes the load. Minimum illumination level at which the load does not switch on is 2 lux. Maximum illumination level at which the load switches on is 2000 lux.

Regulator of delay allows to set time of the load connected to the sensor. Maximum operation time is 12 minutes. When sensor actuates within timer period of activity, countdown starts again.

Range capability regulator allows to set distance of detection of a moving object by a sensor. If sensor is installed at 2,5 m height, minimum position of the regulator is 1 meter, maximum is 4 meters.

+