Explosion-proof equipment plant
section3_logo_img
+7(812) 448-90-90
PRODUCTS SERVICES RESOURCES ABOUT US

Selection of SHORVA type boxes and order placement

x
<
>

CONFIGURATION OF BOXES
EXAMPLE 1: SHORVA121211 (8C4)-1KOV1N(A)-1KOV1N(B)-1KOV1N(D)-1KOV1N(E)- TU 3400-005-72453807-07
ЩОРВА121211 (8C4)-1КОВ1Н(A)-1КОВ1Н(Б)-1КОВ1Н(Г)-1КОВ1Н(Д)- ТУ 3400-005-72453807-07

EXAMPLE 2. SHORVA121211(8RP4)-KOV1N(A)-KOV1(B)-KOV1N(C)- TU 3400-005-72453807-07
ЩОРВА121211(8RP4)-КОВ1Н(A)-КОВ1(Б)-КОВ1Н(В)- ТУ 3400-005-72453807-07


EXAMPLE 3. CONFIGURATION OF TWO SHORVA BOXES
КОМПЛЕКТАЦИЯ ИЗ ДВУХ КОРОБОК ЩОРВА

Boxes may be connected with each other by means of fittings with encapsulation as per GOST 30852.1-2002 (IEC 60079-1:1998)

Main types of terminals used in Exd enclosures**
Type Description
RN1 Screw terminal block 0,2-2,5 sq. mm I=15А V=600V
CBD2 Screw terminal block 0,5-4 sq. mm I=24А V=800V (short marking С)
RN2 Screw terminal block 0,2-4 sq. mm I=24А V=400V
CBD4 Screw terminal block 0,5-6 sq. mm I=32А V=800V (short marking С)
RN4 Screw terminal block 0,2-6 sq. mm I=32А V=275V
CBD6 Screw terminal block 0,5-10 sq. mm I=41А V=800V (short marking С)
CBD10 Screw terminal block 0,5-16 sq. mm I=57А V=800V (short marking С)
CBD16 Screw terminal block 0,5-25 sq. mm I=76А V=800V (short marking С)
CBD35 Screw terminal block 0,5-35/50 sq. mm I=125А V=800V (short marking С)
CBD50 Screw terminal block 1,5-50/70 sq. mm I=150А V=800V (short marking С)
CBD70 Screw terminal block 1,5-95 sq. mm I=192А V=800V (short marking С)
CDА120 Screw terminal block 4-150/185 sq. mm I=269А V=800V (short marking С)
CDА185 Screw terminal block 4-240 sq. mm I=353А V=800V (short marking С)
GPM95BB Screw terminal block busbar+busbar up to 22 mm wide (М8 bolt) I=232А V=1000V
GPM150BB Screw terminal block busbar+busbar up to 32 mm wide (М10 bolt) I=309А V=1000V
GPM240BB Screw terminal block busbar+busbar up to 40 mm wide (М12 bolt) I=415А V=1000V
GPM95BC Screw terminal block busbar (up to 22 mm wide, М8 bolt) + wire 25-120 sq. mm I=232А V=1000V
GPM150BC Screw terminal block busbar (up to 32 mm wide, М10 bolt) + wire 35-185 sq. mm I=309А V=1000V
GPM240BC Screw terminal block busbar (up to 40 mm wide, М12 bolt) + wire 50-300 sq. mm I=415А V=1000V
GPM95CC Screw terminal block wire+wire 25-120 sq. mm I=232А V=1000V
GPM150CC Screw terminal block wire+wire 35-185 sq. mm I=309А V=1000V
GPM240CC Screw terminal block wire+wire 50-300 sq. mm I=415А V=1000V
UT2 Screw terminal block 0,5-4 sq. mm I=28А V=750V
UT4 Screw terminal block 0,5-6 sq. mm I=38А V=750V
UT6 Screw terminal block 0,5-10 sq. mm I=50А V=750V
UT10 Screw terminal block 0,5-16 sq. mm I=69А V=750V
HMM1 Spring terminal block 0,2-2,5 sq. mm I=17,5А V=500V
HMM2 Spring terminal block 0,2-4 sq. mm I=24А V=800V
HMM4 Spring terminal block 0,2-6 sq. mm I=32А V=800V
HMM6 Spring terminal block 0,2-10 sq. mm I=41А V=800V
ТE2 Screw terminal block 0,5-4 sq. mm ground
ТE4 Screw terminal block 0,5-6 sq. mm ground
ТE6 Screw terminal block 0,5-10 sq. mm ground
ТE10 Screw terminal block 0,5-16 sq. mm ground
ТE16 Screw terminal block 0,5-25 sq. mm ground
ТE50 Screw terminal block 1,5-50/70 sq. mm ground
ТE70 Screw terminal block 1,5-95 sq. mm ground

*Application of screw and spring terminals is possible:

CBD, DAS, HMM, TE, RN, RP, TR, CDA, SV, PCE, DT, QTC, MZB, EDM, ST, UT,

WDU, WDK, ZDU, ZDK, WPE, SAK, AKZ, BPL, TPL, SK, UKN

and A ground elements, as well as other types of terminals and busbars upon customer‘s request.

Main types of circuit breakers used in Exd enclosures**
Type Description
A1/6 Circuit breaker 1 pole I=6A
A1/10 Circuit breaker 1 pole I=10A
A1/16 Circuit breaker 1 pole I=16A
A1/20 Circuit breaker 1 pole I=20A
A1/25 Circuit breaker 1 pole I=25A
A1/32 Circuit breaker 1 pole I=32A
A1/40 Circuit breaker 1 pole I=40A
A1/63 Circuit breaker 1 pole I=63A
A1/80 Circuit breaker 1 pole I=80A
A1/100 Circuit breaker 1 pole I=100A
A1/125 Circuit breaker 1 pole I=125A
A1/150 Circuit breaker 1 pole I=150A
A1/250 Circuit breaker 1 pole I=250A
A1/400 Circuit breaker 1 pole I=400A
A2/6 Circuit breaker 2 poles I=6A
A2/10 Circuit breaker 2 poles I=10A
A2/16 Circuit breaker 2 poles I=16A
A2/20 Circuit breaker 2 poles I=20A
A2/25 Circuit breaker 2 poles I=25A
A2/32 Circuit breaker 2 poles I=32A
A2/40 Circuit breaker 2 poles I=40A
A2/63 Circuit breaker 2 poles I=63A
A2/80 Circuit breaker 2 poles I=80A
A2/100 Circuit breaker 2 poles I=100A
A2/125 Circuit breaker 2 poles I=125A
A2/150 Circuit breaker 2 poles I=150A
A2/250 Circuit breaker 2 poles I=250A
A2/400 Circuit breaker 2 poles I=400A
A3/6 Circuit breaker 3 poles I=6A
A3/10 Circuit breaker 3 poles I=10A
A3/16 Circuit breaker 3 poles I=16A
A3/20 Circuit breaker 3 poles I=20A
A3/25 Circuit breaker 3 poles I=25A
A3/32 Circuit breaker 3 poles I=32A
A3/40 Circuit breaker 3 poles I=40A
A3/63 Circuit breaker 3 poles I=63A
A3/80 Circuit breaker 3 poles I=80A
A3/100 Circuit breaker 3 poles I=100A
A3/125 Circuit breaker 3 poles I=125A
A3/150 Circuit breaker 3 poles I=150A
A3/250 Circuit breaker 3 poles I=250A
A3/400 Circuit breaker 3 poles I=400A
A4/6 Circuit breaker 4 poles I=6A
A4/10 Circuit breaker 4 poles I=10A
A4/16 Circuit breaker 4 poles I=16A
A4/20 Circuit breaker 4 poles I=20A
A4/25 Circuit breaker 4 poles I=25A
A4/32 Circuit breaker 4 poles I=32A
A4/40 Circuit breaker 4 poles I=40A
A4/63 Circuit breaker 4 poles I=63A
A4/80 Circuit breaker 4 poles I=80A
A4/100 Circuit breaker 4 poles I=100A
A4/125 Circuit breaker 4 poles I=125A
A4/150 Circuit breaker 4 poles I=150A
A4/250 Circuit breaker 4 poles I=250A
A4/400 Circuit breaker 4 poles I=400A
**Installation of other elements of automation systems in Exd enclosures is possible.


Maximum recommended number of cable glands on sides of SHORVA boxes
Enclosure size Dimension type of thread
01 1 2 3 4 5 6 7 8
Type of thread, R as per GOST 6211, М as per GOST 24705
R/M R/M R/M R/M R/M R/M R/M R/M R/M
SHORVA121211 3/2 2/2 2/2 1/1 1/1 - - - -
SHORVA151512 5/5 4/4 3/3 2/2 2/2 1/1 - - -
SHORVA171712 6/6 5/5 3/3 2/2 2/2 2/2 1/1 - -
SHORVA232316 8/8 8/8 7/8 4/4 3/3 2/2 2/2 2/2 -
SHORVA272721 14/14 14/14 11/11 8/8 6/6 4/4 3/3 2/2 2/2
SHORVA424229 22/22 22/22 18/18 11/12 10/10 8/8 5/5 3/3 3/3

CABLE GLANDS

ГОРЭЛТЕХ производит кабельные вводы для всех видов соединений с различными типами резьбы. Широкий диапазон выпускаемых кабельных вводов позволяет решать всевозможные задачи по подсоединению различного типа небронированных и бронированных кабелей, кабелей с оплеткой, металлорукавов и трубной проводки в корпуса электротехнических аппаратов.

For direct insertion of cables and wires to Exd enclosure, specially developed Exd glands for direct insertion are applied. According to the mandatory requirements, this characteristic is specified in the certificate. This helps to refuse from inlet junction box (except for mining version РВ), which makes the products of "ZAVOD GORELTEX" Co. Ltd. unique compared with products of other companies.

Wide range of produced cable glands helps to solve multiple tasks of connection of various types of non-armored and armored cables, cables in sheath, flexible conduit and pipe conduit into enclosures of electrotechnical apparatuses.

Due to material of construction and special coating, our cable glands can be used in moist and dusty rooms and in highly aggressive ambient conditions. Cable glands are resistant to salt spray and other chemical substances, including hydrogens sulfide and hydrochloric acid vapors, saline and acidic mine waters. For full range of cable glands please follow website page "Explosion-proof cable glands". Interactive selection of an explosion-proof cable gland...>>

 

Table of selection of SHORV, SHORVA boxes and enclosures for application in various branches of industry and cost of product*
Enclosure type
SHORV
SHORVA
SHORV-N
Increasing of the product cost
Low > High
Pharmaceutical plants, indoor installation
5
5
5
Chemical plants, indoor installation
4
5
5
Chemical plants, outdoor installation
5
5
5
Milling plants, indoor installation
5
4
inappropriate
Milling plants, outdoor installation
5
5
inappropriate
Paint manufacturing plants, indoor/outdoor installation
5
5
inappropriate
Gas storage tanks, indoor/outdoor installation
5
5
inappropriate
Wastewater treatment plants, indoor/outdoor installation
5
5
5
Vessel terminals, indoor/outdoor installation
5
5
5
Piers and vessel decks, indoor/outdoor installation
5
5
5
Oil loading terminals, indoor/outdoor installation
5
5
5
Offshore oil and gas platforms, indoor installation
5
5
5
Offshore oil and gas platforms, outdoor installation
5
5
5
Nuclear power plants
5
5
5

5 perfectly fit with long service life

4 meets expectations of reasonable service life

*Note:

  1. The table shows corrosion resistance of the enclosure material, its resistance to exposure caused by pollution, as well as ingress protection degree.
  2. When choosing the enclosure it is important to take into account the ambient environment where the box will be operated. It is especially important for enclosures which are used in hazardous areas, since the enclosure is the essential component of protection. The attention should be particularly paid to the consequences of the corrosion and presence of chemical substances in the atmosphere, as well as probable mechanical impact.
  Cast iron/steel
Plastic
Stainless steel 08Х18Н10
GORELTEX stainless steel* 

Aluminum alloy

(copper >0,1%, iron>0,7%, magnesium >0,1%)

GORELTEX aluminum alloy**
Average service life of enclosure, years 20  4 25 30 5 25
Flameproof joint service life, years Outdoor installation 3 - 15 30 2 20
Indoor installation 5 3 20 30 4 25
Reconditioning (grinding) of flameproof joint+ - - - - -

Cost of enclosures production

low average high high low average
Cost of Ex components installation high low very high very high average low
Possible dimensions of enclosures large small large large average large
Mass of enclosures heavy small heavy heavy average small
Dissipated power high low average average maximum maximum
Application in marine conditions - - + + - +

*Corrosion-resistant stainless chrome-nickel cast steel of "ZAVOD GORELTEX" Co. Ltd.

**Modified corrosion-resistant aluminum alloy (copper ≤ 0,1%, iron ≤ 0,4%, magnesium ≤ 0,1%) of "ZAVOD GORELTEX" Co. Ltd.

Flameproof joint service life defines the duration of use of Exd enclosures in a hazardous area.