PKIE-PKL explosion-proof rocker switchesPURPOSE AND SCOPE OF APPLICATION

PKIE-PKL explosion-proof rocker switches are intended for application in hazardous areas. Explosion-proof rocker switches are the most familiar to the main part of users. Easy principle of operation of the rocker switch enables to assemble convenient and reliable diagrams of lighting control. Large operating surface of the key allows using the switch in protective gloves. The key of the switch is equipped with a canopy for protection against accidental pressing.

Scope of application – outdoor and indoor hazardous areas, mines non-hazardous with gas or dust as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996) regulating application of electrical equipment in hazardous and non-hazardous areas at dangerous production facilities of danger class I, II, III, IV supervised by Rostechnadzor and national technical supervision bodies of the CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ 12.2.007.0-75. ССБТ, ГОСТ Р МЭК 60079-0-2011, ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.1-2002 (МЭК 60079-1:1998), ГОСТ 30852.8-2002 (МЭК 60079-0:1998), ГОСТ 30852.17-2002 (МЭК 60079-18:1992), ГОСТ 30852.20-2002, ГОСТ 30852.10-2002 (МЭК 60079-11:1999), ГОСТ IEC 61241-1-1-2011, ГОСТ Р МЭК 60079-31-2010, ТР ТС 012/2011, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ГОСТ 24754-2013
+
CERTIFICATES
Маркировка взрывозащиты Marking:
 1Ex db e IIC T6...T5 Gb
 0Ex ia IIC T6...T5 Ga
 Ex tb IIIC T85°C...100°C Db
 Ex ia IIIC T85°C...100°C Da
Mining equipment marking:
РН1/РН2
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+40 (Т6/Т85°С)
-60...+60 (Т5/Т100°С)
-60...+60 (for mine normal and general industrial versions)
Maximum voltage, V:
~120, ~220,~380, 12, 24, 110,250
Maximum current, A:
16 (при ~120 V), 10 (при ~220 V), 6 (при ~380 V), 2 (at12 V), 2 (at24 V), 1 (at 110 V), 0,5 (at 250 V)
Enclosure material:
Glassfiber reinforced polyester, chemically resistant to operating environment and resistant to UV radiation
Electric shock hazard protection class:
I (class II upon request)
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Mounting plate
/PLANKA
Breather plug for moisture removal
/VKU
Drain plug for condensate removal
/DKU
Nameplates with light-reflective coating
/SVP
Nameplate with inscription as per customer’s specification
/NADPIS "_"
+
OVERALL AND MOUNTING DIMENSIONS

Габаритные и присоединительные размеры ПКИЕ-ПКЛ


TYPES OF PKIE-PKL EXPLOSION-PROOF ROCKER SWITCHES

PKIE-PKL01 PKIE-PKL02 PKIE-PKL03 PKIE-PKL04
Взрывозащищенный пост ПКИЕ-ПКЛ Взрывозащищенный пост ПКИЕ-ПКЛ Взрывозащищенный пост ПКИЕ-ПКЛ Взрывозащищенный пост ПКИЕ-ПКЛ
- Enclosure with a key switch.
- PGEPKL1Z key 

- Сable gland (size/type is specified when ordering)
- Weight (without cable glands): 0.5 kg
- Enclosure with a key switch
- PGEPKL1Z key       

- Two cable glands (size/type is specified when ordering)
- Weight (without cable glands): 0.5 kg
- Enclosure with a key switch.
- PGEPKL2I key 

- Сable gland (size/type is specified when ordering)
- Weight (without cable glands): 0.5 kg
- Enclosure with a key switch
- PGEPKL2I key

- Two cable glands (size/type is specified when ordering)
- Weight (without cable glands): 0.5 kg
+
FORMATION OF MARKING

For typical control station:

PKIE-P X  /  Х  – TU 27.12.31-037-72453807-2017
          Name of device
          Configuration: KL01, KL02, KL03, KL04
          Options, accessories and versions

Example: PKIE-PKL02-TU 27.12.31-037-72453807-2017


For non-typical control station as per customer‘s specification:

Расположение кабельных вводов
PKIE-P  -  Х Х  ...  Х Х  -  Х   Х  ( Х ) -  Х   Х  ( Х ) /  Х  –  TU 27.12.31-037-72453807-2017
                                              Name of device
                                              Number of control elements
                                              Type of control elements
                                              Number of cable glands
                                              Type of cable gland
                                              Side of cable gland location
                                              Options, accessories and versions

Example: PKIE-PKL-3PGEPKL1Z-2KNV1(D)-TU 27.12.31-037-72453807-2017

- Rocker switch: PKIE-PKL 
- 3 keys PGEPKL1Z 
- 2 cable glands of KNV1 dimension type, side of location (D)
- TU 27.12.31-037-72453807-2017

The enclosure is selected which is the most suitable for arrangement of the selected set of elements.

+
+