Explosion-proof all-weather floor-mounted thermal cabinets GTG-SHKAF (KSH/TERMO-BOX) with electric heating

+
+
x
<
>
Explosion-proof all-weather floor-mounted thermal cabinets GTG-SHKAF (KSH/TERMO-BOX) with electric heatingPURPOSE AND SCOPE OF APPLICATION

Explosion-proof all-weather floor-mounted thermal cabinets GTG-SHKAF with control unit are intended for installation of various equipment (flow meter, pressure and temperature sensors, transducers and other measuring and analytical equipment) inside them that operate in the limited temperature range in hazardous areas and under severe weather conditions.

Explosion-proof all-weather floor-mounted thermal cabinets GTG-SHKAF conform to all norms, rules and requirements to electrical equipment in chemical, oil and gas, mining industries, as well as in other industries, where explosive atmosphere is present.

The temperature inside the thermal cabinet is increased by explosion-proof heater with additional temperature control device. Control of the heating element and power supply is performed through explosion-proof boxes KSRV. If necessary, heating control units may be installed outside the thermal cabinet, thus saving space inside the thermal cabinet for customer‘s equipment. This ensures full explosion protection of heating system of the thermal cabinet. In case of change of outside temperature in the range from -60°С to +45°С, the temperature inside the thermal cabinet, when temperature controller is on, is within the range from +5°С to + 45°С without condensation of moisture. 

Для обеспечения качественной теплоизоляции внутренние стенки термошкафа покрываются специализированным слоем сверхлёгкого теплостойкого металлизированного армированного утеплителя или для усиления теплоизоляции дополнительное покрытие экструзионным вспененным полимером.

Upon customer‘s request, thermal cabinets GTG-SHKAF may be equipped with viewing windows. Sizes of windows depend on type of the used box and place of installation of thermal cabinets.

Depending on customer‘s needs, the temperature inside the thermal cabinet may be regulated using various types of thermostats or using automatic system on the base of programmable logic controller.

Inner cabinet walls are covered with a special layer of ultra-light heat-resistant metalized armored heat insulator for ensuring efficient thermal insulation, or an additional extrusion polymer foam coating is applied to increase thermal insulation.

The explosion protection is ensured by the installation of explosion-proof components in the body of the thermal cabinet.

Scope of application – outdoor and indoor hazardous areas and pits non-hazardous with gas or dust, as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), regulating the application of electrical equipment in hazardous areas, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ 14254-96 (МЭК 529-89), ГОСТ Р МЭК 60079-0-2011, ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.1-2002 (МЭК 60079-1:1998), ГОСТ 30852.8-2002 (МЭК 60079-0:1998), Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ТР ТС 012/2011, ТР ТС 004/2011, ГОСТ 31441.1-2011 (EN 13463-1:2001), ГОСТ 24754-2013, ГОСТ 30852.20-2002
+
CERTIFICATES
Маркировка взрывозащиты Marking:
II Gb или III Db
1Ex d e IIC T3 Gb (для исполнения /ОБОГРЕВfor version /OBOGREV)
Mining equipment marking:
РН1/РН2
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+85
-20...+60 (for РН1, РН2)
Relative air humidity:
98%
Enclosure material:
Low-carbon steel (for GTG-SHKAF-M enclosures)
Stainless steel (for GTG-SHKAF-N enclosures)
Thermal protection:
Low heat-conducting composite materials (without application of mineral wool)
Design life:
up to 25 years
Electric shock hazard protection class:
I
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Non-explosion-proof version
/PROM
Indication of voltage presence on current-conducting wires
/IN
Earthquake-resistant version
/MSK-64
Nameplate with inscription as per customer’s specification
/NADPIS "_"
Heating for automation
/OBOGREV
Inspection window
/O
Internal thermal insulation
/TEPLOIZOLJCIJA
Cable and pipe transits
/KPG
Anti-condensation heating of window
/OBOGREV STEKLA
Additional doors
/DVER
Independent fire suppression system
/ASPT
Fire alarm system module
/PS
Intrusion alarm system
/OS
Forced ventilation system
/VG
Emergency lighting system
/SAO
Reed switches on doors
/DVG-MV2
+
OVERALL AND MOUNTING DIMENSIONS
Взрывозащищенные напольные всепогодные термошкафы ГТГ-ШКАФ с электрообогревом

STRUCTURAL PARAMETERS AS PER CUSTOMER‘S SPECIFICATION

+


Взрывозащищенные напольные всепогодные термошкафы ГТГ-ШКАФ с электрообогревомVarious dimensions of explosion-proof all-weather floor-mounted thermal cabinets GTG-SHKAF are available upon customer‘s request.
+