Explosion-proof cable glands KNVZ (FEC/CP) for encapsulation for non-armored cable

+
+
x
<
>
Explosion-proof cable glands KNVZ (FEC/CP) for encapsulation for non-armored cablePURPOSE AND SCOPE OF APPLICATION

Explosion-proof cable glands KNVZ for encapsulation for non-armored cable are used in places where ingress and explosion protection are required. They secure the cable from accidental pulling out. KNVZ explosion-proof cable glands provide a barrier for non-armored cable.

KNVZ explosion-proof bushing for encapsulation gives the possibility to use KNV cable gland for insertion of non-armored cables with non-circular cross-section or having the structure where the wires do not adjoin tightly.

The structure of encapsulated bushing consists of two elements: a sleeve and a release element. Two-component epoxy composition that is included in the scope of supply is used as a sealant. The main advantage of this composition compared to liquid compound is its plasticity which is good for mounting of cable in cable gland. Apart from plasticity, the epoxy composition ensures high bonding strength, does not shrink, as well as it is resistant to water, oils and solvents.

Increased wall thickness of GORELTEX cable glands bodies considerably enhances their strength compared with cable glands of other manufacturers.

KNVZ cable gland may be used for direct insertion as a part of fireproof enclosures of IIA, IIB+H2, IIC subgroups, which have the volume exceeding 2000 cm3.

KNVZ explosion-proof cable glands are completely suitable for use with equipment having ExnR marking.

KNVZ explosion-proof cable glands may be used with armored/braided cable. A31 earthing element is used to ensure earthing circuit continuity with metal enclosure and protection against electromagnetic disturbances.

Thanks to their design, KNVZ explosion-proof cable glands ensure cable unloading, protection against pulling out without causing damage to the structure of cable sheath and conductors, as well as prevent cable overcompression.

Explosion-proof cable glands of KNVZ series are designed in Russia (Patent No. 155936, rightholder "ZAVOD GORELTEX" Co. Ltd. , operating characteristics of which significantly surpass Russian and foreign analogues.

Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.10-2002 (МЭК 60079-11:1999), ГОСТ 30852.14-2002, ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.8-2002 (МЭК 60079-0:1998), ГОСТ 30852.1-2002 (МЭК 60079-1:1998), ГОСТ Р МЭК 60079-0-2011, ТР ТС 004/2011, ТР ТС 012/2011, РД 5.2-093-2004, ГОСТ IEC 60079-1-2011, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, ГОСТ 24754-2013, ГОСТ 30852.20-2002
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex db IIC Gb
1Ex e IIС Gb
2Ex nR IIС Gc
Ex tb IIIC Db
Mining equipment marking:
РВ Ex db I Mb
РП Ex e I Mc
РН1, РН2
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+185
-60…+130 (for 1Ex d IIC Gb)
Material:
Nickel-plated brass resistant to vapor of hydrogen sulphide, hydrochloric acid and sea fog, NK code
Stainless steel grade 08Х18Н10 as per GOST 5632-2014 (AISI 304) - N
Material of bushing for encapsulation with compound:
Nickel-plated brass resistant to vapor of hydrogen sulphide, hydrochloric acid and sea fog.
(Other materials are available upon request.)
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
External seal for ingress protection (IP) on thread (cylindrical and metric thread)
/UKF
Locknut (cylindrical and metric thread)
/KG
Grounding ring
/A31
Stainless steel grade 03Х17Н13М2 as per GOST 5632-2014 (316L)
/316L
Marine version
/MORE
Non-explosion-proof version
/PROM
+
OVERALL AND MOUNTING DIMENSIONS
CABLE GLAND
КАБЕЛЬНЫЙ ВВОД



BUSHING FOR ENCAPSULATION

ВТУЛКА ПОД ГЕРМЕТИЗАЦИЮ КОМПАУНДОМ

KNVZ cable glands, metric thread GOST 24705 Metric
Cable gland dimension type Thread, GOST 24705 Dimensions, mm Mass, kg
all files
D, mm Ød, mm

Number of wires pulled through cable gland (calculated under outlet Ød). Core cross-section, mm2

Main Alternative АС1 АС2 ØМ L 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150
KNVZ1M FEC1I/CP M20 x 1,5 26 26 28,5 60 0,11 13 10 13 8 6 5 4 2 1 - - - - - - -
KNVZ2M FEC2I/CP M25 x 1,5 34 34 38 64 0,20 18 15 31 20 14 11 9 5 3 1 1 1 - - - -
KNVZ3M FEC3I/CP M32 x 1,5 40 40 44,5 74 0,24 24 23 73 47 34 26 22 11 8 4 4 2 1 1 - -
KNVZ4M FEC4I/CP M40 x 1,5 50 50 56 72 0,40 30 26,5 97 62 45 35 30 15 11 5 5 3 2 1 1 1

KNVZ cable glands, taper inch thread NPT
Cable gland dimension type Thread, NPT Dimensions, mm Mass, kg ØD, mm Ød, mm Number of wires pulled through cable gland (calculated under outlet Ød). Core cross-section, mm2
Main Alternative АС1 АС2 ØМ L 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150
КНВЗ1N FEC1N/CP 1/2" 26 26 28,5 60 0,11 13 10 13 8 6 5 4 2 1 - - - - - - -
КНВЗ2N FEC2N/CP 3/4" 34 34 38 64 0,20 18 15 31 20 14 11 9 5 3 1 1 1 - - - -
КНВЗ3N FEC3N/CP 1" 40 40 44,5 74 0,24 24 23 73 47 34 26 22 11 8 4 4 2 1 1 - -
КНВЗ4N FEC4N/CP 1 1/4" 50 50 56 72 0,40 30 26,5 97 62 45 35 30 15 11 5 5 3 2 1 1 1

Maximum permissible number of wires for encapsulation in bushing depending on the core cross-section.

The specified values conform to paragraph 2.1.2 of Annex C of GOST IEC 60079-1-2011.

+
FORMATION OF MARKING
KNVZ X Х Х / Х  – TU 3400-007-72453807-07
            Cable gland type
            Dimension type
            Thread type: taper inch NPT - N; metric GOST 24705 - M;
Taper pipe GOST 6211-81 - R; pipe cylindrical GOST 6357-81 - G
            Cable gland material: nickel-plated brass - NK, stainless steel - N
            Options, accessories and versions

Example:
KNVZ1MNK -TU 3400-007-72453807-07
- Cable type: non-armored
- Thread: М20x15, metric ISO965
- Material: nickel-plated brass
+
+