Explosion-proof equipment plant
section3_logo_img
+7(812) 448-90-90
PRODUCTS SERVICES RESOURCES ABOUT US

Explosion-proof cable glands KNVTV (FETF) for non-armored cable in hoses, conduits, metal hoses; inner thread for external connection

x
<
>
PURPOSE AND SCOPE OF APPLICATION

Explosion-proof cable glands KNVTV (FETF) for non-armored cable in hoses, conduits, metal hoses are used in areas, where explosion-proof sealing on the cable sheath is required, they protect the cable against accidental pulling out. The distinct feature of explosion-proof cable glands KNVTV is the inner thread for external connection, which helps to connect flexible hoses, conduits, corrugated metal hoses, etc.

The most important development is the use of one sealing ring for the whole range of diameters of crimped cable, which reliably crimps the incoming cable and ensures Exd type of protection. One sealing ring together with mandrel or cable withstand the force in newtons, which is equal to the twentyfold diameter value (in mm) of the mandrel or the cable. This helps to use KOVTVL series explosion-proof cable glands without additional unloading of cable.

Increased wall thickness of bodies of GORELTEX cable glands considerably enhances their strength compared with cable glands of other manufacturers.

KNVTV cable glands may be used for direct insertion as a part of fireproof enclosures of IIA, IIB+H2, IIC subgroups, which have the volume exceeding 2000 cm3.

KNVTV explosion-proof cable glands are completely suitable for use with equipment having ExnR marking.

Thanks to their design, KNVTV explosion-proof cable glands ensure cable unloading. These cable glands ensure protection against pulling out without causing damage to the structure of cable sheath and conductors, as well as prevent cable overcompression.

Explosion-proof cable glands of KNVTV series are designed in Russia (Patent No. 155936, rightholder "ZAVOD GORELTEX" Co. Ltd. , operating characteristics of which significantly surpass Russian and foreign analogues.

Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.