Explosion-proof boxes for connection of heating accessories under heat insulation GTG-VK2 (SA-A2CORD)

+
+
x
<
>
Explosion-proof boxes for connection of heating accessories under heat insulation GTG-VK2 (SA-A2CORD)PURPOSE AND SCOPE OF APPLICATION

GTG-VK2 is an effective solution from GORELTEX for connection and input of cables of electric heating systems under hear insulation which simplifies installation and excludes damage to heating cable during its input under heat insulation, as well as it splices ends of the heating cable for T-shaped branches. GTG-VK2 are applied for all types of GTG heating accessories and cables of third party manufacturers.

Design of OKT-2 supporting brackets enables convenient mounting on the pipe with round cross-section. The box shall be fastened to the pipe with a metal fastening clamp which is included in the set. The clamp ensures reliability of the grounding circuit between the pipe and the enclosure;

Explosion-proof boxes GTG-VK2 enable the connection of up to 3 heating cables, cables of temperature sensor. Type of sealant shall be approved when ordering.

Several OKT-2 supporting brackets can be installed on the enclosure upon customer’s request for the connection of more than 3 heating elements; arrangement of terminal blocks inside the box can be amended. The boxes are manufactured with various height H of the supporting bracket OKT-2 lower than the insulation thickness which ensures sealing of heat insulation and excludes risk of damage to cable at termination points. Mechanical strength of GTG-VK2 considerably outperforms standard direct entry sealed termination units DESTU made of polyester which allows its operation up to -75°С (high quality units DESTU up to -40°С, low cost units only -20°С). Installation of flat heating cables of 17 mm width is possible.

Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), for use in presence of combustible dust, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor and national technical supervision bodies of the Customs Union and CIS countries.

Mechanical strength and resistance to impact loads of supporting brackets ОКТ-2 considerably outperform the analogues made of polyester many of which break down at the temperature of -20°С even in case of small loads.

+
CONFORMITY TO STANDARDS IN RUSSIA
ГОСТ Р МЭК 60079-0-2011, ГОСТ 12.2.007.0-75. ССБТ, ГОСТ 14254-96 (МЭК 529-89), ГОСТ 30852.0-2002 (МЭК 60079-0:1998), ГОСТ 30852.8-2002 (МЭК 60079-0:1998), ТР ТС 012/2011, ТР ТС 004/2011, ГОСТ IEC 61241-1-1-2011, Гл. 7.3 ПУЭ, Гл. 7.4 ПУЭ, РД 5.2-093-2004, ГОСТ 30852.20-2002, ГОСТ 24754-2013, ГОСТ Р МЭК 60079-31-2010
+
CERTIFICATES
Маркировка взрывозащиты Marking:
1Ex db e IIC T6...T4 Gb
Ex tb IIIC T85°С...T135°С Db
Mining equipment marking:
РН1
РН2
Protection:
+
TECHNICAL DATA
Ambient temperature, °С:
-60...+40 (Т6/Т85°С)
-60...+60 (Т5/Т100°С)
-60...+70 (Т4/Т135°С)
60...+85 (Т4/Т135°С)
-60…+85 (for version PH1/PH2)
Maximum voltage, V:
800
Maximum current, A:
175
Size of connected heating cable, mm:
up to 17
Diameter of connected power cable and dimension type of cable gland:
from 6 mm to 12 mm for cable gland KNV1 (by default)
from 12 mm to 18 mm for cable gland KNV2
from 6 mm to 12 mm for cable gland KOV1
from 12 mm to 18 mm for cable gland KOV2
another gland upon customer's request
Grounding:
2 stainless steel ground (inner and outer)
Box coating:
Antistatic polymer epoxy coating, frictionally intrinsically safe, resistant to operating environment and ionizing radiation. Color RAL 7035
Box material:
Modified corrosion-resistant aluminum-silicon alloy, , resistant to salt spray and other chemical substances, including hydrogen sulfide and hydrochloric acid fumes, salty and acidic mine waters, frictionally intrinsically safe
Bracket material:
Nickel plated brass
Fixation on pipe:
1 fastening clamp on pipe
Electric shock hazard protection class:
I
Mass, kg:
3
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
+
DIMENSIONS, OPTIONS, ACCESSORIES
MARKING
Non-explosion-proof version
/PROM
The button is under the glass
/P
Indication of voltage presence on current-conducting wires
/IN
Other bracket height (with order from 1000 pcs.)
/H (___)
Round heating cable
/KGK
Option of temperature sensor connection
/PKT
Version for minimum operating temperature -75°C
/HOLOD
+
OVERALL AND MOUNTING DIMENSIONS

GTG-VK2

КОНСТРУКТИВНЫЕ ПАРАМЕТРЫ ГТГ-ВК2

Sealing rubber for heating cable for GTG-VK2

Уплотнительная резинка под греющий кабель для ГТГ-ВК2

 

 

Type of enclosureDimensions Maximum recommended number of terminals per wire cross-section2
А B C H 1,5 2,5 4
GTG-VK2-111109 112 112 91 150 5 5 4
GTG-VK2-141410 149,5 149,5 107 150 24 22 20
GTG-VK2-171109 172 112 91 150 17 16 14
+
FORMATION OF MARKING
Стороны расположения кабальных вводов
GTG-VK2
 -  Х  -  Х  -  Х  -  Х  /  Х  – TU 3400-005-72453807-07
                      Name of product
                      Size code of enclosure
                      Diameter of heated pipe
                      Type of installed terminals
                      Number and dimension type of cable glands
                      Options, accessories and versions
+
CONFORMITY TO STANDARDS IN RUSSIA
Table of names matching
Previous international name 
"ZAVOD GORELTEX" Co. Ltd. 

TU 3400-005-72453807-07
The Customs Union name

"ZAVOD GORELTEX" Co. Ltd.

TU 3400-005-72453807-07

SA-A2CORD /SA11 GTG-VK2-111109
SA-A2CORD /SA14 GTG-VK2-141410
SA-A2CORD /SA20 GTG-VK2-171109
+