Explosion-proof portable light fixtures SGR01 (EVGC-P12 / EVGC-P24)
PURPOSE AND SCOPE OF APPLICATION Explosion-proof portable light fixtures SGR01 consist of aluminum enclosure with built-in socket and fire- and impact-resistant globe which is mounted to the body by means of thread. Light fixtures have eye bolt or a hook for suspension.
Scope of application – outdoor and indoor hazardous areas as per explosion protection marking, GOST 30852.13-2002 (IEC 60079-14:1996), areas with presence of combustible dust, as per GOST IEC 61241-3-2011, dangerous production facilities of I, II, III, IV hazard class supervised by Rostechnadzor of the RF and national technical supervision bodies of the Customs Union and CIS countries.

Marking:

1Ex db IIC Т6 Gb

Ex tb IIIC T82°С Db
Certificates and permits:
TU 27.40.39-028-72453807-2017
Ambient temperature, °С:
-60…+40/+50/+60
Rated voltage of power supply unit, V:
~ 220 (50/60 Hz)
Rated supply voltage of light fixture, V:
⎓12, ⎓24, ~36
Electric diagram:
Direct connection to terminals L, N, PЕ of 4 mm2 cross section. Supply voltage 12 V. (Socket 12 V or a set socket+power supply unit 220 V/12 V upon request)
Enclosure material:
Modified corrosion-resistant aluminum-silicon alloy, resistant to salt spray and other chemical substances, including hydrogen sulfide and hydrochloric acid fumes, salty and acidic mine waters, frictionally intrinsically safe. Globe - fire- and impact-resistant glass.
Correlated color temperature, K:
5000 (for SGR01-...S)
4000 (for SGR01-...S with /160 option)
Cable cross-section:
2,5 mm2 or 4 mm2
Electric shock hazard protection class:
I / III (for power up to 42 V)
Mass of one light fixture without cable, kg:
2,1
Climatic version:
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1, W5)
OVERALL AND MOUNTING DIMENSIONS
POWER SUPPLY UNIT 220 V/12 V
POWER SUPPLY UNIT 220 V/12 V WITH ONE SOCKET
Explosion-proof light fixtures SGR01
Model
Lamp power or luminous flux
Ex marking
Type of lamp
SGR01-40INC
40 W
Gas-Dust
Incandescent
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Incandescent
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+40
Dust
Ex tb IIIC T82°С Db
-60…+40
SGR01-60INC
60 W
Gas-Dust
Incandescent
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Incandescent
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+40
Dust
Ex tb IIIC T82°С Db
-60…+40
SGR01-75INC
75 W
Gas-Dust
Incandescent
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Incandescent
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+40
Dust
Ex tb IIIC T82°С Db
-60…+40
SGR01-12ELS
12 W
Gas-Dust
Fluorescent compact
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Fluorescent compact
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+50
Dust
Ex tb IIIC T80°С Db
Ex tb IIIC T70°С Db
-60…+50
-60…+40
SGR01-15ELS
15 W
Gas-Dust
Fluorescent compact
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Fluorescent compact
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+50
Dust
Ex tb IIIC T80°С Db
Ex tb IIIC T70°С Db
-60…+50
-60…+40
SGR01-25ELS
25 W
Gas-Dust
Fluorescent compact
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
Fluorescent compact
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+50
Dust
Ex tb IIIC T80°С Db
Ex tb IIIC T70°С Db
-60…+50
-60…+40
SGR01-8SC
8 W
Gas-Dust
LED
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
LED
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+60
Dust
Ex tb IIIC T79°С Db
Ex tb IIIC T69°С Db
Ex tb IIIC T59°С Db
-60…+60
-60…+50
-60…+40
SGR01-12SC
12 W
Gas-Dust
LED
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
LED
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+60
Dust
Ex tb IIIC T79°С Db
Ex tb IIIC T69°С Db
Ex tb IIIC T59°С Db
-60…+60
-60…+50
-60…+40
SGR01-15SC
15 W
Gas-Dust
LED
Details
Rated voltage, V
12DC, 24DC
Socket
Е27
Lamp type
LED
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+60
Dust
Ex tb IIIC T79°С Db
Ex tb IIIC T69°С Db
Ex tb IIIC T59°С Db
-60…+60
-60…+50
-60…+40
SGR01-1240S
1240 lm
Gas-Dust
LED matrix
Details
Rated voltage, V
12DC, 24DC, 36AC
Lamp type
LED matrix
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+60
Dust
Ex tb IIIC T72°С Db
Ex tb IIIC T62°С Db
Ex tb IIIC T52°С Db
-60…+60
-60…+50
-60…+40
SGR01-2480S
2480 lm
Gas-Dust
LED matrix
Details
Rated voltage, V
12DC, 24DC, 36AC
Lamp type
LED matrix
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+60
Dust
Ex tb IIIC T78°С Db
Ex tb IIIC T68°С Db
Ex tb IIIC T58°С Db
-60…+60
-60…+50
-60…+40
SGR01-3720S
3720 lm
Gas-Dust
LED matrix
Details
Rated voltage, V
12DC, 24DC, 36AC
Lamp type
LED matrix
Mass, kg
2,85
Ex-marking and ambient temperature
Gas
1Ex db IIC Т6 Gb
-60…+50
Dust
Ex tb IIIC T76°С Db
Ex tb IIIC T66°С Db
-60…+50
-60…+40
OPTIONS, ACCESSORIES AND VERSIONS
MARKING
Non-explosion-proof version
/PROM
Earthquake-resistant version
/MSK-64
Set: power supply unit 220 V/12 V with a socket and a plug
/BP
Version for nuclear facilities "Small leak"
/MALAJA TECH
Explosion-proof plug type VGM
/VGM
Light fixture preservation
/KONSERVACIJA
Note:
- The /KXX option is required.
- The /LAMP option is not applicable for SGR01-1240S, SGR01-2480S and SGR01-3720S.
- Option /160 is applicable only for SGR01-1240S, SGR01-2480S and SGR01-3720S.
FORMATION OF MARKINGFORMATION OF MARKING OF PORTABLE LIGHT FIXTURE
SGR01 |
- |
Х |
Х |
- |
Х |
/ |
Х |
/ |
Х |
– TU 27.40.39-028-72453807-2017 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of device |
|
|
|
|
|
|
|
|
|
|
Lamp power |
|
|
|
|
|
|
|
|
|
|
Lamp type: incandescent lamp - INC; Compact fluorescent with spiral tube - ELS;
LED lamp - SC;
LED matrix - S |
|
|
|
|
|
|
|
|
|
|
Supply voltage, V: 12DC; 24DC; 36AC |
|
|
|
|
|
|
|
|
|
|
Number of light fixtures: 1; 2; 3 |
|
|
|
|
|
|
|
|
|
|
Options, accessories and versions (including / KXX - required option) |
EXAMPLE OF ORDER:SGR01-2480S-12DC/1/К40/KRYUK-TU 27.40.39-028-72453807-2017
FORMATION OF MARKING OF STATIONARY POWER SUPPLY UNIT
SHGVA-BP-SGR01 |
- |
Х |
- |
Х |
- |
Х |
/ |
Х |
– TU 27.12.31-048-72453807-2017 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type of device |
|
|
|
|
|
|
|
|
|
Number of sockets: 1; 2; 3 |
|
|
|
|
|
|
|
|
|
Supply voltage, V: 12DC; 24DC; 36AC |
|
|
|
|
|
|
|
|
|
Dimension type of cable gland |
|
|
|
|
|
|
|
|
|
Options, accessories and versions |
EXAMPLE OF ORDER: SHGVA-BP-SGR01-3-12DC-KOV1N-TU 3400-006-72453807-07
EXAMPLE OF ORDER: SHGVA-BP-SGR01-1-12DC-KOV1N-TU 27.12.31-048-72453807-2017
Selection matrix of minimum cross-section of supply cable. Supply voltage 12 V
Supply voltage 12 V |
Cable length, m |
5 |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
60 |
Light source power, W: |
10 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,5 |
1,5 |
1,5 |
1,5 |
2,5, |
2,5 |
20 |
1,0 |
1,0 |
1,0 |
1,5 |
1,5 |
2,5 |
2,5 |
2,5 |
4,0 |
4,0 |
4,0 |
4,0 |
40 |
1,0 |
1,5 |
2,5 |
2,5 |
4,0 |
4,0 |
6,0 |
6,0 |
6,0 |
6,0 |
|
|
60 |
1,0 |
2,5 |
4,0 |
4,0 |
6,0 |
6,0 |
|
|
|
|
|
|
100 |
1,5 |
4,0 |
6,0 |
6,0 |
|
|
|
|
|
|
|
|
150 |
2,5 |
6,0 |
|
|
|
|
|
|
|
|
|
|
200 |
4,0 |
6,0 |
|
|
|
|
|
|
|
|
|
|
Selection matrix of minimum cross-section of supply cable. Supply voltage 24 V
Supply voltage 24 V |
Cable length, m
|
5 |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
60 |
Light source power, W:
|
10 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
20 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
40 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,0 |
1,5 |
1,5 |
1,5 |
1,5 |
2,5 |
2,5 |
60 |
1,0 |
1,0 |
1,0 |
1,0 |
1,5 |
1,5 |
2,5 |
2,5 |
2,5 |
2,5 |
2,5 |
4,0 |
100 |
1,0 |
1,0 |
1,5 |
1,5 |
2,5 |
2,5 |
4,0 |
4,0 |
4,0 |
4,0 |
6,0 |
6,0 |
150 |
1,0 |
1,5 |
2,5 |
2,5 |
4,0 |
4,0 |
4,0 |
6,0 |
6,0 |
6,0 |
|
|
200 |
1,0 |
1,5 |
2,5 |
4,0 |
4,0 |
6,0 |
6,0 |
|
|
|
|
|
Selection matrix of cable gland depending on cross-section and type of supply cable
Type of cable |
Cable outer diameter |
Cable gland type |
KG 3х1,0 |
9,1 |
KNV1 |
KG 3х1,5 |
10,1 |
KNV1 |
KG 3х2,5 |
12 |
KNV2 |
KG 3х4 |
14,5 |
KNV2 |
KG 3х6 |
16,6 |
KNV2 |
GOST 14254-96 (IEC 529-89), GOST 30852.0-2002 (IEC 60079-0:1998), GOST R IEC 60079-31-2010, GOST 30852.1-2002 (IEC 60079-1:1998), GOST IEC 61241-1-1-2011, RD 5.2-093-2004, Ch. 7.3 PUE, Ch. 7.4 PUE, TR CU 004/2011, TR CU 012/2011